Chapter 2 Analog Input
relative to non-sigma-delta modules in the system. This input delay is specified in the C Series
I/O module documentation.
Slow Sample Rate Modules
(NI cDAQ-9184/9188) Some C Series analog input modules are specifically designed for
measuring signals that vary slowly, such as temperature. Because of their slow rate, it is not
appropriate for these modules to constrain the AI Sample Clock to operate at or slower than their
maximum rate. When using such a module in the cDAQ chassis, the maximum Sample Clock
rate can run faster than the maximum rate for the module. When operating at a rate faster than
these slow rate modules can support, the slow rate module returns the same point repeatedly,
until a new conversion completes. In a hardware-timed task, the first point is acquired when the
task is committed. The second point is acquired after the start trigger as shown in Figure 2-2.
Figure 2-2. Sample Clock Timing Example
For example, if running an AI task at 1 kHz using a module with a maximum rate of 10 Hz, the
slow module returns 100 samples of the first point, followed by 100 samples of the second point,
etc. Other modules in the task will return 1,000 new data points per second, which is normal.
When performing a single-point acquisition, no points are repeated. To avoid this behavior, use
multiple AI timing engines, and assign slow sample rate modules to a task with a rate at or slower
than their maximum rate.
Refer to C Series Support in NI-DAQmx for more information. To access this document, go to
ni.com/info and enter the Info Code rdcdaq.
AI Start Trigger Signal
Use the Start Trigger signal to begin a measurement acquisition. A measurement acquisition
consists of one or more samples. If you do not use triggers, begin a measurement with a software
command. Once the acquisition begins, configure the acquisition to stop in one of the following
ways:
When a certain number of points has been sampled (in finite mode)
After a hardware reference trigger (in finite mode)
With a software command (in continuous mode)
StartTrigger
Data from
A/D Conversion
(Slow Module)
SampleClock
Data Returned
to AI Task
1st A/D Conversion 2nd A/D Conversion 3rd A/D Conversion
A
BC
AA ABB BC